Adjusting the Spray Pattern (see figure E)
Never actuate the trigger switch 9 while adjusting the
air cap 3.
Application
Initial coatings, corners, edges
and hard to reach locations
Large-surface top coatings
Adjusting the Spraying Capacity (see figure F)
– To adjust the requested spraying capacity, turn the thum-
bwheel 7:
I: Min. spraying capacity,
IIII: Max. spraying capacity.
Spraying capacity
Too much material on target
area:
Not enough material on target
area:
Adjusting the Air Flow (see figure G)
– Turn control knob 24 to adjust the air flow and the pres-
sure for the spray material being used.
Minimal air flow
It is recommended to start with the maximum air flow.
Bosch Power Tools
– Adjust the desired spray-jet width using adjusting lever 2.
– Turn the air cap 3 to the requested position.
Adjusting lever 2
Air cap 3
Adjustment
The spraying capacity must
be reduced.
– Turn the thumbwheel 7 in
direction I.
The spraying capacity must
be increased.
– Turn the thumbwheel 7 in
Work Breaks and Transport (see figure H)
direction IIII.
During work breaks, the spray gun 1 can be placed into the
set-down port 25. The holding device ensures that the spray
gun is tightly seated in the set-down port. Spray material can-
not run out or escape.
– Place down the spray gun on the set-down port and push in
The base unit comprises a carrying handle for easy transport
of the fine-spray system.
Maximum air
flow
– Completely empty the container 10.
– Place down the spray gun on the set-down port and push in
Spray jet pattern
Vertical compact jet for hori-
zontal coating direction
Horizontal compact jet for
vertical coating direction
Vertical wide jet for horizon-
tal coating direction
Horizontal wide jet for verti-
cal coating direction
Air Flow
Adjustment
Too much fog of coating
The air flow must be re-
material:
duced.
– Turn control knob 24 to-
Atomisation too coarse:
The air flow must be in-
creased.
– Turn control knob 24 to-
against the resistance until tightly seated.
Make sure that the spray gun 1 contains no more paint:
Spray the spray gun empty.
against the resistance until tightly seated.
English | 17
ward the left.
ward the right.
1 619 929 K18 | (18.11.11)