or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
The hood is provided with a special power cable ; if the cable
is damaged, request a new one from Technical Service.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
•
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
In the case of the presence of panels and/or walls and/or
lateral wall units check that there is sufficient space to install
the hood and that access to the command panel is easy.
Only for some models
An aesthetic flue can be purchased as an optional accessory.
Check with the authorized dealer whether the model in your
possession envisages this possibility.
We advise installing the hood after having purchased the flue
to check with certainty the most suitable installation.
Fig. 5-14-15-16-17
Operation
T1. Lights ON/OFF
T2. Speed decrease
Press "T2" button to decrease the speed from 4
(intensive) to 1.
Press "T2" button during operation at speed 1, the hood
sets to OFF.
T3 Speed increase
Press T3 button and the hood sets from OFF to speed 1.
Press the button (hood ON) to increase the speed of the
motor from 1 to 4 (intensive).
The respective LED goes on for each speed.
Speed 1 - LED 1
Speed 2 - LED 2
Speed 3 - LED 3
Speed 4 (Intensive) - LED 4 (flashing)
The intensive speed is timed. Standard timing is 5', at the
end of which the hood sets to speed 2.
To deactivate the function before time is up press T2
button, the hood sets to speed 3.
T4 Speed timing
Speed timing is activated by pressing T4 button, when
timing is up the hood switches off.
Timing is divided as follows:
Speed 1 - 20 minutes (LED 1 flashing)
Speed 2 - 15 minutes (LED 2 flashing)
Speed 3 - 10 minutes (LED 3 flashing)
Speed 4 (Intensive) - 5 minutes (LED 4 flashing)
During timed operation press T2 button and the hood quits the
timed mode and decreases the speed.
Press T3 button and the hood quits the timed mode and
increases the speed.
Press T4 button and the hood quits the timed mode
maintaining the set speed.
Grease filter signal
After 40 hours of operation LED 1 flashes.
When such signal appears the grease filter installed needs to
be washed.
To reset the signal, keep T4 button pressed for 5".
The hood gives out a "BEEP" and LED 1 stops flashing.
Charcoal filter signal
After 160 hours of operation LED 2 flashes.
When such signal appears the charcoal filter installed must be
replaced.
To reset the signal, keep T4 button pressed for 5".
The hood gives out a "BEEP" and LED 2 stops flashing.
18