BINDING INSTALLATION INSTRUCTIONS
The SOUND WAVE should only be in-
stalled in Kaldewei bathtubs provided
for this purpose.
When installing the SOUND WAVE and
connecting it electrically, protect the
surface of the bathtub from damage.
An inspection opening (200 mm ×
200 mm) is to be provided in the
area of the control.
The control unit is to be arranged at
a height of at least 60 mm above the
floor.
ELECTRICAL CONNECTION
The electrical connection and correc-
tion of faults and defects should only
be effected by a specialist company.
For the electrical connection, a sup-
ply line 2 × 1.5 mm² should be avail-
able at the installation site.
In the supply line, a main switch iso-
lating all poles with a contact open-
ing of at least 3 mm for switching off
the SOUND WAVE should be provided
(non-use, servicing work).
6
Only a certified electrical fitter is
allowed to open the control unit. Any
warranty claims will become void on
unauthorized opening of the control
unit.
All work has to be carried out using
special technical tools.
Kaldewei recommends to provide the
bathtub with suitable sound insula-
tion from the building structure. You
will find suitable sound insulation
products in our bathtub accessories.
The installation is planned for a supply
with AC voltage of 230 V 50/60 Hz.
The electrical connection shall be
protected by a 16 A fuse and be only
made via a residual current-operated
circuit breaker (30 mA).
If the components are converted, the
warranty becomes void.
SOUND WAVE