Warning
• Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
• All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made
by others for any reason or for the use of non-original accessories or materials.
• All the products comply with the requirements of Directive 2006/95/EC (which replaced Directive 73/23/EEC and subsequent amendments), as certifi ed by the CE mark they carry.
• Do not insert objects or pour liquids into the device.
• Installation, mounting and assistance procedures for electrical devices must only be performed by specialised electricians.
• Cut off the power supply before carrying out any maintenance work.
INTRODUCTION
This manual contains information for wiring and starting up a basic single-family kit system consisting of one external unit Art. 4682KC and
software Art. 1454K. For complete ViP system installation and wiring information, please refer to the relevant technical manual, which is also
available from the website www.comelitgroup.com.
KIT CONTENTS
• 1 porter module Art. 33411 (Kit Art. 8501I) or Art. 3268I/1 (Kit Art. 8504) + corresponding audio/video unit Art. 4682KC
• 1 power supply unit for external unit Art. 1595
• 1 USB support loaded with PC-Intercom software Art. 1454K
The ViP address of the software is set to 00000001 "Master" by default,
while the ViP address of porter module Art. 33411 (Kit Art. 8501I) or Art. 3268I/1 (Kit Art. 8504) + corresponding audio/video
unit Art. 4682KC is set to 00000100.
Guide to fi tting a network cable for connecting the PC to Comelit switch Art. 1440
The recommended cables are:
• UTP (Unshielded Twisted Pair): not protected from electromagnetic interference, maximum length 100 metres. We recommend the use of a
Panduit cable code NUL5C04BU-CE.
• STP (Shielded Twisted Pair): similar to the UTP but with a metal sheath.
The UTP and STP can fall into various categories. Category 5 (CAT 5) cables or greater must be used for the ViP system.
The tools required for fitting are as follows:
• 6-P 8-P crimping pliers.
We recommend using 8-pole Panduit pliers code MPT5-8A.
• 2 RJ45 connectors for each section of cable.
We recommend using Panduit connectors code MP588-L.