Troubleshooting
Fault
Cause
The generator
Too much oil in the engine.
tends to stall.
Load is over 2.6 kW.
Carburettor is not receiving any
petrol.
Air intake is blocked.
Inverter is damaged.
Electromagnet is blocked.
Air filter is dirty.
The generator is
Inverter is damaged.
running but does
The stepper motor is faulty or the
not supply any
cable is disconnected.
voltage.
Electromagnet is blocked.
The throttle valve is blocked.
The generator
Inverter is damaged.
starts up very
The stepper motor is faulty or the
fast and then the
cable is disconnected.
"GENERATOR
ALERT" mes-
sage appears.
The generated
Inverter is damaged.
voltage is unsta-
The stepper motor is faulty or the
ble.
cable is disconnected.
30
TEC29, TEC29LPG
Remedy
➤ Drain the oil.
➤ Reduce the consumers.
➤ Clean the carburettor.
➤ Check the air filter (see chap-
ter "Servicing the air filter
(fig. 7, page 6)" on page 27).
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.
EN