▶ Store the tool and battery in a place that is as cool and dry as possible.
▶ Never store batteries in direct sunlight, on heating units or behind a window pane.
▶ Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶ Check the tool and batteries for damage before use after long periods of storage.
9 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
The tool doesn't work.
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
The tool or battery gets very
hot.
10 Disposal
WARNING
Risk of injury. Hazards presented by improper disposal.
▶ Improper disposal of the equipment may have the following consequences: The burning of plastic
components generates toxic fumes which may present a health hazard. Batteries may explode
if damaged or exposed to very high temperatures, causing poisoning, burns, acid burns or
environmental pollution. Careless disposal may permit unauthorized and improper use of the
equipment. This may result in serious personal injury, injury to third parties and pollution of the
environment.
▶ Dispose of defective batteries right away. Keep them out of reach of children. Do not disassemble
or incinerate the batteries.
▶ Batteries that have reached the end of their life must be disposed of in accordance with national
regulations or returned to Hilti.
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
11 Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
12 FCC statement (applicable in US) / IC statement (applicable in Canada)
The product complies with part 15 of the FCC Rules and RSS­210 of the IC.
Operation is subject to the following two conditions:
This device shall cause no harmful interference.
This device must accept any interference received, including interference that may cause undesired
operation.
Printed: 31.07.2017 | Doc-Nr: PUB / 5260659 / 000 / 01
Possible cause
The battery is not fully inserted.
Low battery.
Very low ambient temperature.
The retaining lugs on the battery
are dirty.
Electrical fault.
Action to be taken
▶ Push the battery in until it
engages with an audible click.
▶ Change the battery and charge
the empty battery.
▶ Warm up the battery slowly to
room temperature.
▶ Clean the retaining lugs and refit
the battery.
▶ Switch the tool off immediately,
remove the battery, keep it
under observation, allow it to
cool down and contact Hilti
Service.