Télécharger Imprimer la page

LaserLiner CompactCube-Laser 3 Mode D'emploi page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure
it produces accurate measurement results. We recommend carrying out
calibration once a year.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing
for longer periods. Store the device in a clean and dry place.
Technical data
Self-levelling range
Accuracy
Operating range (depending
on room illumination)
Laser wavelength
Laser class
Power supply
Operating time
with laser cross at front
with all laser lines
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight (incl. batteries)
EU directives and disposal
This device complies with all necessary standards for the
free movement of goods within the EU.
This product is an electric device and must be collected
separately for disposal according to the European
Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=comcublas3pl
CompactCube-Laser 3
(Subject to technical alterations. 21W04)
± 3°
± 0.5 mm / m
15 m
635 nm
2 / < 1 mW
3 x 1.5 V alkaline batteries (type AAA)
approx. 20 hours
approx. 9 hours
0 ... 40°C, max. humidity 80% rH,
no condensation, max. working altitude
4000 m above sea level
-10 ... 70°C, max. humidity 80% rH
69 x 69 x 65 mm
285 g
13
EN

Publicité

loading