Reference Earth
An addi onal earth stake is required to measure the earth system performance.
a)
Install a single galvanised stake (G878 / G879) at least 60cm (2 ) long, at least
10m (33 ) from the main energizer earth system and at least 10m (33 ) from
any mains cabling, telephone cabling, water pipes or building earth.
b)
Using Underground Cable (G627) connect the reference earth stake to the
black (ref earth symbol) terminal on the energizer.
Step 3. Connect the fence
WARNING: do not turn energizer on un l a er installa on is complete.
a)
Connect the energizer's red output ( ) terminal to the fence using
Underground Cable (G627). Remove 5cm (2") of plas c coa ng from one end
of the cable. Unscrew the red (FENCE) terminal and insert the wire through the
terminal slot. Screw the terminal closed, ensuring the wire is fi rmly clamped.
b)
A ach the other end of the cable to the fence using a Joint Clamp (G603).
For instruc ons on fence installa on see the Gallagher Electric Fence Guide or go to
www.gallagher.com
10
Gallagher 3E4347 MB1800i MB2800i Energizer User Manual
GREEN
To Earth System
BLACK
To Reference Earth
RED
To Fence