Télécharger Imprimer la page

IMG STAGELINE TXS-865 Mode D'emploi page 8

Masquer les pouces Voir aussi pour TXS-865:

Publicité

Les langues disponibles

Les langues disponibles

indication are displayed), select a different
GB
frequency.
2) Switch on the transmitter, check its settings
(
instruction manual of the transmitter),
then set it to the same transmission fre-
quency via the REMOSET function according
to chapter 6.2.
When the transmitter and the receiver
have been set to the same frequency, the
muting function is deactivated; the indication
MUTE (f) disappears. One of the indications
or
(c) is displayed to show which of the
antennas (1) receives the more powerful
radio signal. The indication RF (a) shows the
reception quality: the more segments dis-
played, the better the reception.
If the reception is poor, please check
– if the batteries of the transmitter are ex -
hausted.
The display shows a battery symbol (d)
indicating the status of the batteries in the
transmitter in four 4 levels. If the batteries
are exhausted (indication
backlight will change from green to orange.
– if the transmission power of the transmitter
is too low.
To increase the transmission range when
the transmitter and the receiver are placed
at a greater distance, it is possible to
increase the transmission power from
10 mW to 50 mW (possible for transmitter
TXS-865HT only,
the transmitter).
– if the reception is disturbed by objects in
the transmission path.
Make sure to keep the transmitter and the
receiver at a minimum distance of 50 cm
from metal objects and any other sources
of interference, e. g. electric motors or fluo-
rescent lamps.
– if the reception is improved when you
move the antennas.
– if the squelch threshold adjusted with the
corresponding SQUELCH control is too
high
step 5.
3) Speak / sing into the microphone of the trans-
mitter or, in case of an instrument micro-
phone, feed an audio signal to the micro-
phone. The indication AF (b) shows the
volume level of the audio signal received.
The more segments of the indication AF dis-
played, the higher the level.
Set the transmitter to the optimum volume
via the indication AF
the transmitter.
4) If the volume level is too high for the subse-
quent unit, it will be possible to attenuate it by
10 dB or 20 dB. For each audio output, an
attenuation switch is provided: the corre-
sponding switches ATTENUATION CH 1 and
CH 2 (13) for the two XLR outputs (11); the
switch ATTENUATION (15) for the 6.3 mm
output jack (14).
5) Use the control SQUELCH (12) to adjust the
threshold for interference suppression of the
corresponding receiver unit. The further the
control turned clockwise, the higher the
threshold.
Interference suppression will mute the
receiver unit when high-frequency interfer-
ence signals with a level below the threshold
adjusted are received during music intervals.
With a higher threshold, however, the trans-
mission range will decrease as the receiver
unit will also be muted when the intensity of
the radio signal of the transmitter falls below
the threshold adjusted. Therefore, adjust a
higher threshold with the control SQUELCH
8
when the reception is good; select a lower
value when the transmitter and the receiver
are placed at the greater distance.
6) Each receiver unit is provided with a lock
function to prevent accidental change of set-
tings or switching off
To switch off the unit, keep the button POWER
(4) pressed for a few seconds. If the receiver is
not in use for a longer period of time, disconnect
the power supply unit from the mains socket;
even when the receiver is switched off, it will
have a low power consumption.
6.1 Adjusting the receiver unit
When the receiver unit is not locked, press the
button SET (8) to activate the setting modes one
after another:
group (keep button pressed for a while) → chan-
nel → scan function → identification number
→ lock function
To make settings in a setting mode, see the cor-
responding chapter 6.1.1 to 6.1.4.
), the display
To exit a setting mode without changing a set-
ting, press the button SET repeatedly until the
display briefly shows
receiver unit will then return to the normal mode.
6.1.1 Transmission frequency
To set the transmission frequency, select the
channel group and the channel. Six channel
instruction manual of
groups with preset channels in different numbers
are available
To prevent interference, carefully match the transmis-
sion frequencies of all transmission paths to one
another. In case of parallel operation of several chan-
nels, it is recommended to use channels from the
same group.
1) Keep the button SET (8) pressed until the let-
ter "G" starts flashing on the display; the
group setting mode is activated.
2) Select the group (
(7) or the button
3) Press the button SET to confirm. The letters
"CH" start flashing on the display; the channel
setting mode is activated.
4) Select the channel with the button
When the scan function has been activated
(
selected, the unit will check if the correspond -
ing transmission frequency is presently
being used for transmission (brief insertion
instruction manual of
already used will be skipped.
Note: It will not be possible to set both receiver units
to the same channel of a group. The channel used
for one receiver unit will be locked for the other one.
5) Press the button SET to confirm. The display
briefly shows
unit will return to the normal mode.
6.1.2 Scan function
The scan function makes it easier to select a free
transmission frequency: When the function has
been activated, the frequencies already being
used for transmission will be skipped when
you set the transmission frequency (
ter 6.1.1).
1) Keep the button SET (8) pressed until the let-
ter "G" starts flashing on the display; the
group setting mode is activated.
2) Press the button SET repeatedly until the dis-
play shows the current setting for the scan
function:
chapter 6.1.4.
(= cancel). The
(group / channel)
table in chapter 7.1.
...
)
with the button
(9).
chapter 6.1.2), each time a channel is
= "scan channel"). If it is, this channel
(= store). The receiver
scan function activated
scan function deactivated
3) Press the button
or the button
.
4) Press the button SET to confirm. The display
briefly shows
return to the normal mode.
6.1.3 Identification number
To set the transmitter via the REMOSET function
to the transmission frequency of the receiver unit
(
chapter 6.2), both must have the same iden-
tification number.
1) Keep the button SET (8) pressed until the let-
ter "G" starts flashing on the display; the
group setting mode is activated.
2) Press the button SET repeatedly until the dis-
play shows
number ( ...
3) Select the desired number with the button
(7) or the button
4) Press the button SET to confirm. The display
briefly shows
return to the normal mode.
5) Then set the identification number on the
transmitter
transmitter.
6.1.4 Lock function
When the lock function has been activated, the
REMOSET function will not be available for the
receiver unit (
modes, you will only be able to activate the mode
for the lock function in order to deactivate the
lock.
Furthermore, it will not be possible to switch
off the complete TXS-862 when at least one of
the two receiver units has been locked.
Activating the lock
1) Keep the button SET (8) pressed until the let-
ter "G" starts flashing on the display; the
group setting mode is activated.
2) Press the button SET repeatedly until the dis-
play shows
starts flashing.
3) To activate the lock, press the button
The display shows
or
.
4) Press the button SET to confirm. The display
briefly shows
return to the normal mode.
The indication LOCK (e) on the display
shows that the lock has been activated.
When you press a button,
addition.
Deactivating the lock
1) Keep the button SET (8) pressed until the
indication LOCK (e) starts flashing on the dis-
play.
2) To deactivate the lock, press the button
The display shows
3) Press the button SET to confirm. The display
briefly shows
the normal mode.
6.2 Automatic frequency matching
(REMOSET function)
chap-
Via a 2.4 GHz radio signal of the corresponding
receiver unit, the transmitter is matched to the
transmission frequency of this unit. The range of
REMOSET transmission may reach up to 10 m.
Transmission is not possible when the receiver
unit is locked (deactivating the lock
6.1.4).
After setting the desired transmission fre-
quency on the receiver unit (
and switching on the transmitter, press the but-
(7) to select the setting
(9) to select the setting
. The receiver unit will
and the current identification
).
(9).
. The receiver unit will
instruction manual of the
chapter 6.2). From the setting
(lock off) and LOCK (e)
(9).
.
. The receiver unit will
appears in
(7).
.
. The unit will return to
chapter
chapter 6.1.1)

Publicité

loading

Ce manuel est également adapté pour: