• Remove the pipes or hoses on the suction side and on the pressure side.
• Remove the filter basket. (→ Cleaning the device)
• After removing the impeller unit, clean all parts under running tap water.
• Replace a worn or damaged impeller unit.
• Assemble the pump in the reverse order.
Storage/winter protection
The unit is frost-proof to -20 °C. If lower temperatures are expected, remove the unit
and place it in storage.
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Store the pump submerged and in a frost-free environment.
28
ARS0054