3. Adjust the length of the harness until the harness
support hook is in level with your right hip.
To connect the battery charger
1. Connect the battery charger to the voltage and
frequency that is specified on the rating plate.
2. Put the plug in a grounded socket outlet. The LED
on the battery charger flashes green one time.
Note: The battery does not charge if the battery
temperature is more than 50 °C/122 °F. If the
temperature is more than 50 °C/122 °F, the battery
charger makes the battery become cool before the
battery charges.
To connect the battery to the
product
WARNING: Only use Husqvarna original
batteries with the product.
1. Make sure that the battery is fully charged.
2. Push the battery into the battery holder of the
product. The battery locks into position when you
hear a click.
12
CAUTION: If the battery does not move
easily into the battery holder, the battery
is not installed correctly. This can cause
damage to the product.
3. Make sure that the battery is installed correctly.
Battery information
Refer to the operator's manual of the battery for
information about how to use the battery.
To fill with chain oil
Fill with chain oil after 1 hour of operation or when the
battery is empty.
1. Open the chain oil cap on top of the saw head.
2. Fill with Husqvarna chain oil.
3. Attach the chain oil cap.