Télécharger Imprimer la page

PLYMOVENT SMARTONE Manuel Opérateur page 7

Publicité

Les langues disponibles

Les langues disponibles

mounting instruction
1. By using the universal filter brackets (K) the filter can
be mounted at the wall or in hanging position from the
ceiling.
Mounting of floor rack RS-1 (accessory)
2. Mount the legs (A) 4 pcs to the filter sides.
3. Mount the cross section parts (B) and (C) to the leg
frame.
4. Lift up the filter in upright position.
5. Divide the fan collar (D) and fan (E), fit the collar to the
filter side and re-fit collar and fan together.
6. Put the dust-bin (F) under the hopper (G), and connect
hose (H) between. Fixate the upper and lower part of
the hose with hose clamps.
7. Connect the inlet air ducting (I) on top of filter.
8. The outlet air (filtrated air) (J) can be taken out from 3
different sides of the filter, or through the direct mounted
fan.
071113/0 SmartOne
K
a
b
a
D
e
J
J
K
a
c
a
D
e
g
h
f
J
i
J