fault finDing chart
fault
•
Green operating Led
don't light
•
Red alarm Led is flashing.
•
Compressed air valve fails to
open, or does not close.
•
Timer problems
•
High pressure drop/
low airflow.
replacement of fuses
before changing a broken fuse an authorized electrician must do necessary measurements (controls).
inside the electrical control box 3 fuses are situated.
a) Disconnect the mainpower by turning the main switch in position off (0).
b) open the door on control box.
c) change the broken fuse.
fuse f1- primary side of transformer- placed at the bottom of the control box
fuse f2- secondary side of the transformer- placed at the bottom of the control box.
fuse f3- control fuse- placed at the circuit card.
CE DECLARATION
if the fault remains, please contact plymovents customer service
CE Declaration of Conformity for machinery
We, Plymovent Manufacturing B.V., Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the product:
•
SmartOne
which this declaration refers to, is in accordance with the
conditions of the following Directives:
•
EMC 2004/108 EC
•
LVD 2006/95 EC
071113/0 SmartOne
Smart"one"
•
the main supply voltage
the manoeuvre fuses
•
the fuse for the fan and the valve output
( placed at the circuit boad ).
•
the fuse on the circuit board
•
that the flow direction on the valve is in accordance
with the airflow.
•
that the pressure in the compressed air system is
max 5 bar.
•
that the control voltage from the transformator is
24 v ac.
•
that there is no shortcircuit in the electrial coil
( compressed air valve).
•
that all potentiometers are adjusted in a correct way.
pulse, pause, cycles.
•
that the fan is turning in right direction.
•
that the pressure in the compressed air system is
max 5 bar.
•
that the collected particles are dry.
•
that "off line cleaning" is used.
checK