OPERATION
9.8.2 jAR CYClE RUN vIA ExTERNAl SUCTION
This method can be performed on table-top models equipped with the suction valve.
1) Start-up. Switch the machine on via the main switch.
2) Activate the cycle "jARS NO STOP". Press the "PUMP" button: the displays show the words "jARS
SElECT". Press the "SEl" key to scroll through the list of the JARS programs.. Select "jARS NO STOP" .
3) Tighten the rubber holder fitting
closed position.
4) Apply the suction device
as far as possible in the fitting
5) Start-up the cycle by lowering the lid. Wait until the vacuum gauge
value of -1.0 bar and open the valve
depression has been created between the device and the lid, and the lid and the container. From
the moment the vacuum gauge on the control panel
wait a further 4-5 seconds for the maximum vacuum to be created.
B
6) Close the valve
. Remove the device
E
Close the valve
immediately. Proceed with the next container or end the cycle by pressing the
"STOP" button.
7) End the cycle by pressing the "STOP" button. The jar function remains enabled: to go back to the
bag packaging functions, press the "PUMP" button again.
A
OPEN
ClOSED
B
52
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
A
on the attachment. Make sure the valve
C
to the rubber holder fitting
A
.
B
. Press the device
C
by tilting it sideways.
F
A
. Push the pipe
D
C
firmly on to the lid until sufficient
D
indicates the maximum value of -1.0 bar,
C
D
B
is in the
F
of the device
indicates the maximum
E