Annex 3 : Maximum peak power calculation
Some devices will require a higher startup power than the operating power. This specificity must be
considered.
Peak power = Equipment nominal power × start-up coefficient
See below some example of equipments showing difference between the operation power and the
minimum acceptable power for the inverter.
Equipment
FR
FR
EN
To identify the exact power of your equipment, please consult the manufacturer datasheets on the
device manual.
Note: Calculations have been done for mono-phase devices.
IMEON 3.6 : Overload power capability at nominal voltage (AC
96
IMEON INVERTER
Operating power
Electric oven
2 500 W
Television
300 W
Portable
900 W
grinder
Circular saw
1 100 W
Freezer
300 W
Single phase
1 500 W
compressor
Washing
3 000 W
machine
OUTPUT)
Manuel d'installation / Installation guide IMEON Inverter – Rev B.5
Start-up Coefficient
Maximum peak power
1
1
2,5
2,5
3,5
3,5
3,5
IMEON 9.12 : Overload power capability at nominal
voltage (AC OUTPUT)
2 500 W
300 W
2 250 W
2 750 W
1 050 W
5 250 W
10 500W