18
Measuring range, 0 bar...
Effect of temperature on
sensitivity in the nominal (rated)
excitation voltage range per 10K,
rel. to actual value
in the nominal (rated)
temperature range
in the operating temperature
range
Effect of temperature on zero
signal in the nominal (rated)
excitation voltage range per 10 K,
rel. to nominal (rated) sensitivity
in the nominal (rated)
temperature range
in the operating temperature
range
Excitation voltage
Reference excitation voltage
Nominal (rated) excitation
voltage
Operating range
Ambient conditions
Permissible voltage between
measuring circuit and transducer
ground at reference temperature
Material
of parts in contact with the
measurement medium
of parts in contact with the
environment
Reference temperature
Nominal (rated) temperature
range
Limiting temprature range
Storage temperature range
Impact resistance (tested according to DIN EN 600 68-2-29)
Impact acceleration
Impact duration
Impact form
Acceleration sensitivity per 10
m/s2 for exciting frequencies of
20% of natural frequency
Mechanical specifications
Degree of protection
(per DIN 40050, IEC 529)
Pressure connection
Tightening torque
Mounting position
Electrical position
P3IC/10 ... 3000 bar
Weight without cable approx.
HBM
bar
10
20
50
%
%
%
%
V
V
V
V
1.4542 / 1.4301
1.4301 / 1.454 / 1.4542, chloroprene / silicone
°C
°C
°C
‐40...+100 (...120°C up to 24 hours)
°C
2
m/s
ms
-
%
N⋅m
PUR cable, 5 m long, free ends
g
100 200
500 1000 2000
"0.1
"0.2
"0.1
"0.15
5
0.5 ... 7.5
0.5 ... 12
50
1.45
42
23
‐10...+80
‐50...+100
1000
4
Half sine wave
t"0.001
IP67
M12x1.5
30
any
M12 sensor plug, 8 pins
200
P3IC / P3ICP
3000
2500
1.4548
M20x1
.5
A2382-3.0 en/de/fr

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Industrial class p3icp

Table des Matières