Drufosmart
Problem
Cause
Electronics can be set,
Heating element is not
but radiator does not
swivelled-in completely
heat
Micro-switch defect
Heating time elapses,
Quartz radiator defect
but radiator does not
heat
Temperature monitor
was activated
Heating time elapsed,
Lifetime of quartz
blank is not plasticized
radiator exceeded
sufficiently
Heating time was
too short
Unit does not reach the
Line pressure too low
pre-adjusted pressure
Unit makes fizzy sounds
Ventilation valve
during thermoforming
not closed
Tension ring has
been placed wrongly
into plate reception
Connection hose
leaky between valve
and cylinder
38
Aid
Swivel the heating
element in correctly
Micro-switch has to be
exchanged by an expert
Exchange quartz
radiator
Exchange temperature
monitor
Exchange quartz
radiator
Prolong heating time
by 5–10 sec.
Increase line pressure
Close ventilation valve
Put tension ring into
correct position
Unit has to be
controlled by an
expert, connection hose
has to be exchanged,
if necessary
15. Spare part list
No.
Description
5
Heating handle
6
Insert bowl with nub plate
7
Drawer for granules
9
Compressed air connection, complete
10
Handle plate reception
11
Plate reception
12
Ventilation valve
13
Tension ring
17
Housing red
19
Micro-switch
20
Heating housing
21
Quartz-infrared-radiator
22
Temperature monitor
23
Pillar heating element
25
Magnetic valve
26
Cylinder
27
Display foil, adhesive
28
Limit plate reception
29
Support plate reception
30
Pillar plate reception
31
Bottom plate
33
Mains supply / fuse carrier
34
Activation lever
35
Connector lever / axis
36
Bushings
37
Final switch activation lever
38
Final switch heating
39
Recuperating spring
40
Lever axis
43
Main switch
without drawing no.
Power cord Europe
Power cord England
Power cord America
Electronics incl. display, key pad, connection cable
Specify supply voltage or serial number.
Fuse F3.15 AT
O-rings 112 x 3 mm
Cable harness complete
Limit heating element
D6505519
50591/50592
5565
55637
D6505519
D6505512
50761
D50038
D65555R
55790
D6505513
D6505542
5542
55773
52021230
52019
55820
D6555344
D6505514
55772
D6505511
51208
D65885
D65017
55708
E5521
55790
55861/55862
D6555847
50841
51021
51284
51283
55201
51321
51077
55521
D65016
39

Publicité

Table des Matières
loading

Table des Matières