INSTRUCTION ON MOUNTING AND USE
Check also the drawings on the initial pages with the alphabetical
and numerical references in the explanatory text.
Closely follow the instructions in this manual. We cannot
accept liability for any faults, detriment or fire damage to the
appliance due to non-compliance with the manual's
instructions. Installation and electrical connections must be
executed by a qualified technician. You should affix the hood
to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard. Do not install it inside a cupboard.
Attach it to the wall using the anchors provided.
Installation
The cooker hood must be placed at a minimum distance of 65
cm from the cooking plane for electric cookers and 75cm for
gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface
mounting only. Do not fix chimney flue to furniture or fly over
shelves unless the chimney flue can be easily removed, in
case maintenance is ever required.
Use
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe not supplied).
If cooking fumes and vapours cannot be externally discharged,
the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
Electrical connection
Make sure that there is a power socket near the hood and
that the system has a 30 mA differential. The mains voltage
must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it
does have a plug, connect the hood to an accessible
approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum
contact opening of no less than 3 mm (accessible). This
installation and electrical connection must be executed by a
qualified technician.
Operation
3
Push
2
ANTI-ODOUR FILTER ACTIVATION WARNING:
If the hood is installed in filter mode, the anti-odour filter
saturation warning must be activated, indicating when the
filter needs to be replaced.
With the hood off, press and hold the knob for a few seconds
– the function will be enabled or disabled: 4 green flashes
for the symbol (F) indicate the function is enabled, whereas
4 red flashes indicate it is disabled.
Press the Push key to activate the hood; the four 4 icons will
light up in blue. Press these icons lightly to enable them and
enter a specific function. The hood will memorize the latest
selected settings, i.e. aspiration power and lights.
1
F
MOTOR BUTTON
Press this control button to start up the motor,
aspiration power selected before it was last switched
the green pilot light will light up. Turn the knob clockwise or
counter-clockwise to increase or decrease the
power: the light
indicators in this section (1) show the
aspiration power,
which varies from 0 to 4. After 5 seconds,
if no action is taken on the knob, the system will exit the
motor function and the green pilot light will turn blue once
again, disabling the possibility of changing settings.
Press the control button a second time while it is still green
to power off the motor and exit the function.
Automatic heat sensor functioning:To select this function,
press the motor button and turn the handle in an anti-
clockwise direction until the light on the motor button begins
to flash. The temperature sensor will start the motor, selecting
the right aspiration speed. The speeds will vary in
accordance with the change in temperature from the cooking
top.
LIGHTS BUTTON
Press this control button to switch the lights on over the
stove (at maximum intensity); the pilot light will light up to
green. After 5 seconds, if no action is taken on the knob, the
system will exit the light function and the green pilot light will
turn blue once again, disabling the possibility of changing
settings.
Press the control button a second time while it is still green
to power off the lights and exit the function.
TIMER BUTTON
Press this control button to enable the hood's timer function;
the pilot light will light up to green. Turn the knob clockwise or
counter-clockwise to increase or decrease the automatic
shutdown timer:
the light
the set time, from 5-10-20-40 minutes. After 5 seconds, if no
action is taken on the knob, the system will exit the timer
function and the green pilot light will turn blue once again,
disabling the possibility of changing settings.
Press the control button a second time while it is still green to
reset the timer to zero and exit the function.
F
FILTERS BUTTON
The hood features two warnings, one for the saturation of the
anti-odour filter (if the function has been activated) and the
other for the metal filter.
The red pilot light will light up when the control button is
pressed once, showing the metal filter's saturation condition.
When the control button is pressed a second time the pilot
light will turn purple, showing the saturation condition of the
anti-odour filter, if previously activated; in this case, the light
indicators in this section (1) show the degree of saturation of
the filters.
When the timer for the metal filter reaches 40 hours, the pilot
light will flash red to indicate that the metal filter must be
cleaned, whereas it will flash purple after 120 hours to indicate
that the anti-odour filter needs to be replaced.
(at the same
aspiration
indicators in this section (3) show
off);