Maintenance • Mantenimiento
Before maintenance work always ensure that the
device is:
pressureless
de-energized
Maintenance recommendation:
Remove 2 pan head screws (1) and lift off
Q MAT 02. The elbow adaptor stays in
place.
Disconnect discharge hose (2).
Turn the 6 pan head screws (3) until heads
are level with the outer edge and take off
diaphragm seat (4).
Replace wear parts (x).
Reassemble Q MAT 02 unit in reverse
order.
Q MAT 02 Wear Parts Kit (x) - 2001365
Functional test of Q MAT 02 device:
Briefly press test button.
Valve opens for condensate discharge.
14
1
(x)
Power
Valve
Quincy Compressor-Q MAT 02 Condensate Drain
Antes de cada trabajo de mantenimiento:
Despresurice el Q MAT 02
Desconecte la corriente eléctrica
Recomendaciones para el mantenimiento:
Desenroscar los 2 tornillos cilíndricos (1) y
quitar el Q MAT 02. El adaptador queda
montado.
Desmontar el tubo flexible (2) de la
salida.
Desenroscar los 6 tornillos cilíndricos (3),
quitar el asiento de la membrana
Cambiar las piezas de desgaste (x)
Montar el Q MAT 02 correctamente.
Q MAT 02 Juego de piezas de desgaste (x)
- 2001365
(x)
(x)
(x)
4
3
Control del funcionamiento Q MAT 02:
Accione el pulsador "TEST" durante 2
segundos.
È la válvula abre para la evacuación del
condensado.
TEST
Alarm
(x)
(x)
(x)
2

Publicité