Télécharger Imprimer la page

Buffalo DM869 Mode D'emploi page 5

Masquer les pouces Voir aussi pour DM869:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Disconnect from power by removing the plug, allow to cool before wiping exterior surfaces and
removing any loose debris.
Unit should be regularly descaled using a food safe descaler.
Troubleshooting
Fault
Appliance does not
heat
No power
Slow to Heat
Error message E01 is
displayed
LCD Display does not
switch on
Technical Specifications
Model
Voltage
DM869
230V 50Hz
DM869_ML_A5_v6_20190829.indb 5
Probable Cause
No power
Power switch is set to OFF
Auto re-set activated
Unit needs descaling
Water level is too low
Power switch is set to OFF
Power
Current
620W
2.8A
Solution
Make sure the appliance is plugged in
correctly
Set the power switch to ON
This product is fitted with a thermal
protector. Allow unit to cool for 30-45
minutes
Descale the appliance
Add water, making sure the water level is
between the MIN and MAX line
Set the power switch to ON
Dimensions
(h x w x d mm)
280 x 415 x 260
UK
Weight
7.5kg
5
2019/8/29 13:18

Publicité

loading