BOMANN DU 652.1 IX Mode D'emploi page 42

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Assembly
WARNING:
 When assembling or inserting the extraction filter
as well as the carbon filter, the appliance must not
be connected to the mains.
 Failure to use the mounting fixtures may lead to a
risk of electric shock.
CAUTION:
 Before mounting, check that the wall has enough
load capacity to bear the cooker hood.
 When drilling the holes in the wall always make
sure that no existing electrical cables or other ob-
jects are damaged.
 Make sure that the ventilation slots are clear of
obstacles and are not covered.
NOTE: Recommendations for preparation work
 When installing, ask another person to assist.
 Wear protective gloves to prevent injuries from
any sharp edges.
01
Fig. 1
A Shaft closure bracket
B Shaft middle bracket
Fig. 2
02
03
C Suspension housing
D Securing housing
Fig. 2a
Fig. 3
Fig. 5
Fig. 7
 Determine the position of the cooker hood central-
ly above the cooking area in accordance with the
specified safety distances.
Totally 9x mounting holes with a diameter of approx.
8 mm are necessary for the wall mounting. Insert the
supplied dowels [Fig. 1].
 First, drill the holes for attaching the housing ac-
cording to the enclosed drilling template. Check
the markings with a spirit level!
Fasten the bracket (01) for suspending the
-
housing with the 3x ST4*40mm screws.
 Fix the bracket (02) for the upper shaft closure
with the screws 2x ST4*40mm; after determining
the extension length of the shaft cover.
 Before attaching the housing, insert the non-
return valves by lightly bending them from above
into the connecting piece (extraction duct) [Fig. 2].
42
Fig. 4
Fig. 6