Installation
NOTE
To prevent scratches, lay paper or a kitchen towel over the edges of the
lower flue duct to protect the surface.
Complete Installation
• For non-vented (recirculating) installations only, install charcoal
filters over metal grease filter. See the "Accessories" section.
• Install metal filters. See the "Maintenance" section.
8
English
Electrical Connection
WARNING
Electrical shock hazard.
WARNING
Shut off power at the circuit breaker panel or fuse box before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Electrically ground the blower.
Connect the ground wire to the green and yellow ground wire in the
terminal box. Failure to do so can result in death or electrical shock.
1. Shut off power at the circuit breaker panel or fuse box.
2. Remove the terminal box cover.
3. Remove the knockout in the terminal box cover and install a UL listed
or CSA approved
⁄
" strain relief.
1
2
4. Run the home power supply cable through the strain relief, into
the terminal box.
A
E
D
C
B
A. Home power supply cable
B. UL listed wire connectors
C. White wires (N)
5. Use UL listed wire connectors and connect the black wires (D)
together.
6. Use UL listed wire connectors and connect the white wires (C)
together.
7. Connect the green (or bare) ground wire from the home power supply
to the yellow-green ground wire (E) in the terminal box using UL listed
wire connectors.
8. Tighten the strain relief screw.
9. Install the terminal box cover.
10. Turn on the power.
To get the most efficient use from your new range hood, read the
"Maintenance" section. Keep your Use, Care, and installation Guide close
to the range hood for easy reference.
D. Black wires (L)
E. Green (or bare) and
yellow-green ground