12. When finished, disconnect the clamps in reverse sequence of connecting procedure—
first disconnect negative (black), then positive (red) clamps. Do not let the clamps touch
each other.
13. Disconnect the jumper cable assembly from the unit.
14. When convenient, using either AC or DC charging adapter, completely charge the
iOnBoost battery.
15. Store the unit and charge adapters in a cool, dry environment, away from flammable
materials. Remember to fully charge the unit every three months.

TROUBLESHOOTING

Jumpstart Warning Lights
The iOnBoost is ready to jumpstart when the cables are connected and a steady green light
illuminates on the cable safety block. The following chart displays the combinations of warning
lights that occur when the iOnBoost fails to display the ready light:
Warning lights
Flashing red
and green
lights
Solid red and
green lights
Solid red light
(no green)
Flashing red
light with alarm
(no green)
Flashing red
and green with
alarm
10
Type of warning
No vehicle battery detected
Cables are not making a
good connection
Vehicle battery voltage too
high for jumpstarting
30-second timer has
expired; the smart cable has
shut down
iOnBoost charge is too low
for jumpstarting
Short-circuit or reverse
polarity
Over heating
Reverse charge
www.wagan.com
®
Solution
Check cable connection.
Check terminals for corrosion.
Make sure the iOnBoost is fully charged.
Check with a mechanic for other starting
related issues.
Disconnect cables from both the battery
and the iOnBoost and follow connection
procedure again.
The iOnBoost needs to be recharged.
Disconnect immediately and follow proper
connection procedure again.
Disconnect and allow unit to cool for 10
minutes.
Disconnect the iOnBoost from the vehicle
battery immediately.