Description; Field Of Application; Installation - Vimar Eikon 20446 Notice Technique

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40

1. DESCRIPTION.

Flush mounting electronic time-thermostat for ambient temperature
control (heating and air conditioning), daily/weekly programming,
supply voltage with 2 AA LR6 1 .5 V batteries (provided), 5(2) A 250
V~ change-over relay output .

2. FIELD OF APPLICATION.

The appliance is designed to control room temperature by acting on
the control circuit of the burner or circulation pump (heating) or on
the control circuit of the air conditioner (air conditioning), ensuring an
ideal temperature, every day, throughout the week .
The large display shows the room temperature, day, time, system
operating status and the daily temperature profile set for the cur-
rent program .
20 - ENGLISH

3. INSTALLATION.

The appliance must be installed in flush or surface mounting boxes
with Eikon, Arké and Plana frames and plates at a height of 1 .5 m
off the floor in a suitable position for correctly detecting the ambient
temperature . It must not be installed in niches, behind doors and
curtains or in areas affected by sources of heat or atmospheric fac-
tors . In particular, it must not be installed on outer walls or in
association with appliances that generate heat (e.g. dimmers
or lamps).
It should be used in dry, dust-free places at a temperature between
0 °C and +40 °C .

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arké 19446Plana 14446

Table des Matières