Télécharger Imprimer la page

SPIT AC 1630P Notice D'utilisation page 13

Masquer les pouces Voir aussi pour AC 1630P:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
▶ Carefully remove the PE emptying and disposal bag from the
container.
▶ Dispose of gathered material in accordance with legal require-
ments.
7.3 Insert fleece filter bag
NOTE
Only use fleece filter bags for dry vacuum cleaning.
▶ Slide the flange completely over the intake socket
NOTE
Operating the rotary slide
▶ Turn the red rotary slide inside to position CLOSE to the stop
on the marker ▲.
7.4 Insert PE emptying and disposal bag*
NOTE
Only vacuum cleaners with dust class M and H with special
containers and rotary slide in the intake socket of types iPulse M,
iPulse H and iPulse H-asbestos are suitable for the use of PE
emptying and disposal bags.
NOTE
Operating the rotary slide
▶ Turn the red rotary slide inside to position OPEN to the stop
on the marker ▲.
▶ Slide the flange completely over the intake socket.
▶ Place the upper bag opening over the container rim.
8
Changing the filter
8.1 Changing the folded filter cartridges
▶ Clean the filter cartridges before changing them.
▶ Turn the lock on the latch through 90° in a counter-clockwise
direction with a coin or similar object and push the latch to the
rear.
▶ Fold up the cover.
▶ Immediately isolate the folded filter cartridges that you have
removed in a dust-tight plastic bag and dispose of properly in
accordance with the requirements.
▶ Insert new folded filter cartridges.
▶ Lift the locking bracket up, fold down the cover and click in place
with light pressure.
9
Changing the motor protection filter
NOTE
If motor protection filter is contaminated, this indicates defective
filter cartridges.
▶ Replace folded filter cartridges.
▶ Replace motor protection filter or wash the motor protection
filter under flowing water, dry and re-insert.