Télécharger Imprimer la page

SPIT AC 1630P Notice D'utilisation page 11

Masquer les pouces Voir aussi pour AC 1630P:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
4
Commissioning
4.1 Before every use
Make sure that the following conditions are met:
r Vacuum cleaner, mains cable, suction hose and accessories
are not damaged.
r All filters have been inserted and are not damaged.
4.2 Switching on and off
The plug socket on the vacuum cleaner remains always under
voltage, regardless of the main switch position.
l WARNING!
Danger of injury by automatically starting power tool!
▶ Switch off power tool or pneumatic tool before connecting to
the vacuum cleaner.
NOTE
With switch in position >0<, the plug socket on the vacuum
cleaner can be used as an extension cable.
l Power consumption: vacuum cleaner + connected power
tool (max. 2000 W) max. 16 A.
4.2.2 Switching on the vacuum cleaner
Functions see „3 Display and control elements"
▶ Insert plug into plug socket.
▶ Set switch to position >I<.
↳ Vacuum cleaner starts immediately.
or:
▶ Set switch to position >A< or >AC<.
↳ Vacuum cleaner is in standby mode for power tools.
4.2.3 Setting the suction hose diameter*
▶ Set suction hose diameter at the switch.
CAUTION
l
Selector switch for minimum air volume flow signal (horn and
light) on vacuum cleaners with dust classes „M" and „H"
In the modes >A< and >AC< the following setting is made,
depending on the diameter of the hose:
Selector switch for
suction hose inner diameter
∅ 35 mm
∅ 27 mm
∅ 21 mm
No speed regulation is carried out. The vacuum cleaner
always runs at max. speed
4.2.4 Adjusting the suction power*
▶ Adjust motor speed on the switch.
▶ Set auxiliary air slide on the handle tube.
4.2.5 Switching off the vacuum cleaner
▶ Set switch to position >0<.
▶ After switching off, pull the mains plug out.
▶ Roll up mains connection cable.
▶ Store the mains connection cable on the cable hook.
▶ Store the suction tube by inserting it into the accessories holder*
▶ Put the suction hose ends together so that no dirt particles leak
▶ Remove Power tool.
5
5.1 Sucking up dry materials
▶ Only use a dry filter, vacuum cleaner and accessories, so that
▶ When vacuuming soot, cement, plaster or similar dusts: Insert a
▶ Always use disposal bags in combination with folded filter
5.2 Sucking up liquids
!
Volume air flow
70 l/s
41 l/s
25 l/s
▶ Vacuum cleaning without fleece filter bags.
or
↳ Vacuum cleaner is switched off.
on the container rear wall.
out.
Operating modes
the dust does not stick and or cake.
PE disposal bag in the dirt container.
cartridges.
NOTE
M, H and H-asbestos class vacuum cleaners should be
preferably used as vacuum cleaners for dry dusts.
l WARNING!
Electrical shock hazard!
▶ If any foam or liquid is discharged, immediately switch off the
vacuum cleaner.
▶ Empty dirt container and folded filter cartridge.
NOTE
Regularly clean the water level sensors (1)
and inspect for signs of damage.
1
1
The folded filter cartridge designed for wet vacuum cleaning.
The built-in sensor switches the motor off when the container is
full. The handling of the vacuum cleaner can be compromised
by a full container.
11