Register
Data content
address
110
Error Protect Code
111
Maximum of Ts
112
Minimum of Ts
113
Display temperature Tx
114
Remaining hot water
115
Auxiliary Status bit: 1
116
Compressor running time
117
Model
118
Main PCB firmware version
119
Wire controller firmware ver- 1~99 indicates the wire controller version serial number.
80
15 PROTOCOLE MO DBUS
Remarks
1~19
E0~E9,EA,Eb,EC,Ed,EE,EF,EH,EL,EP
20~38
P0~P9,PA,Pb,PC,Pd,PE,PF,PH,PL,PP
39~57
H0~H9,HA,Hb,HC,Hd,HE,HF,HH,HL,HP
58~76
C0~C9,CA,Cb,CC,Cd,CE,CF,CH,CL,CP
77~95
L0~L9,LA,Lb,LC,Ld,LE,LF,LH,LL,LP
96~114
b0~b9,bA,bb,bC,bd,bE,bF,bH,bL,bP
unit: °C./ °F
Send value = actual value
unit: °C. / °F
Send value = actual value
unit: °C.
Send value = actual value*2+30
unit: °F.
Send value = actual value
Segment:0~4
BIT15
BIT14
BIT13
BIT12
BIT11
BIT10
BIT9
BIT8
BIT7
BIT6
BIT5
BIT4
Wifi Connection Status(1 Connect 0 No Connect)
BIT3
BIT2
Defrost (1 = active)
BIT1
Solar kit on/off
BIT0
Vacation mode
(1 = active)
Compressor running time, unit: sec, send value = actual value
1-2 means the size of unit (1=190,2=300S)
1~99 Indicates machine version, which refers to the serial number of the hydrau-
lic module version.
(Reserved)