4 Settings
Tab.11
Navigation for installer level
Display
Level
Installer
Installer
(1) See the column "Submenu" in the following table for the correct navigation. The signals are grouped in specific functionalities.
Tab.12
Signals at installer level
Code
Display text
AM200
Status contact 1
AM201
Status contact 1
Tab.13
AM012 - Status
Rang
Status
e
0
Standby
1
Heat Demand
2
Burner Start
3
Burning CH
4
Burning Dhw
5
Burner Stop
6
Pump Post Run
8
Controlled Stop
9
Blocking Mode
10
Locking Mode
11
Load test min
12
Load test CH max
13
Load test DHW max
15
Manual Heat Demand
16
Frost Protection
19
Reset In Progress
21
Halted
23
Factory test
200
Device Mode
254
Unknown
Tab.14
AM014 - Sub status
Rang
Status
e
0
Standby
1
AntiCycling
10
Menu path
> SCB-01
> Installation Setup > SCB-01 > Submenu
Description
Status of status contact 1. The meaning is
dependant on the current function setting.
Status of status contact 1. The meaning is
dependant on the current function setting.
4.3.3
> Parameters, counters, signals > Signals
(1)
Range
0 = Off
1 = On
0 = Off
1 = On
SCB-01 status and sub-status
Explanation
The appliance is in standby mode.
A heat demand is active.
The appliance starts.
The appliance is active for central heating.
The appliance is active for domestic hot water.
The appliance has stopped.
The pump is active after the appliance stopped.
The appliance does not start because the starting
conditions are not met.
A blocking mode is active.
A locking mode is active.
Low load test mode for central heating is active.
Full load test mode for central heating is active.
Full load test mode for domestic hot water is active.
Manual heat demand for central heating is active.
Frost protection mode is active.
The appliance resets.
The appliance has stopped. It must be reset manually.
The factory test mode is active.
The service tool interface controls the functions of the
appliance.
The actual state of the appliance is undefined.
Explanation
The appliance waits for a process or an action.
The appliance waits to restart, because there were too
many consecutive heat demands (anti-short cycle).
Subme
nu
Status
informati
on
Status
informati
on