28
5.0 MAINTENANCE
AND CARE
5.1 Cleaning, maintenance and storage
5.1.1 Warning! Power off the unit using the
operating switch and disconnect the 12 V auto-
motive plug from the vehicle's 12 V receptacle or
the separate power station with built-in 12 V
storage battery.
5.1.2 Clean the equipment with a dry cloth. Do
not use liquids or harsh cleaners as these may
cause discolouration and damage the unit's sur-
face, and possibly damage the unit! Do not allow
liquids to enter the equipment! Do not immerse the
unit in liquids! Only operate the unit when dry.
5.1.3 Only keep / store the unit in dry environ-
ments! Moisture can damage the unit's electron-
ics!
5.1.4 Do not store the unit in extreme temperature
fluctuations! This will result in condensation, which
can damage the electronics!
6.0 TECHNICAL
DATA
Product description: Multicompressor MV 10
Item number:
97181
Dimensions:
approx. 24.5 x 13.3 x 21
cm (l x w x h cm)
Weight:
approx. 1.55 kg
Fuse:
15 A (Ampere)
Operating
temperature:
0 C - 50 C (Celsius)
Compressor:
Compressor output: max. 10 bar / 145 PSI
(bar / PSI = pressure unit)
Pressure indicator /
Manometer gauge: Analogue pressure
readout, not calibrated,
with backlight
Manometer
tolerances:
+/- 0.34 bar (5 PSI) at
0 – 6.9 bar (0 -100 PSI)
+/- 0.48 bar (7 PSI) at
6.9 - 10 bar (100 -150 PSI)
Noise level:
95 dB (dB = volume)
Interval operation:
max. 10 minutes operation,
min. 10 minutes cool down
Generator set:
1 cylinder, 1 membrane
Oil-free
Air hose length:
approx. 65 cm
Lighting:
Light type:
4 LED lights
LED lights:
LED lights are not
replaceable
Laser class:
LED lights correspond to
Protection Class I
Units with protective
insulation with Protection
Class II
The unit complies with
EC Directives
▪ Machinery Directive
▪ Directive on
°
°
(2006/42/EC)
electromagnetic
compatibility
(2004/108/EC)