Operating the unit
• Please plug the unit in and press the button
• Please press the buttons
humidity level can be set between 30% and 90% in 5% interval.
• When the ambient humidity is about 2% less than the set humidity level, the compressor
will stop and the ventilator keeps working for further 3 minutes. If the ambient humidity as
high as the set humidity level or higher by 3%, the compressor protection function switches
on; the compressor switches off and turn on again 3 minutes later.
• Please press the button
• When the unit is off, please press the button
When the unit is on, please press this button to set the off-time (1-24h).
The set time will not be changed if the defrosting function will be activated or if the
compressor stops due to full water tank.
• Please press the button
the rapid drying of the laundry. Also, you can use this mode use to dehumidify the room air
quickly.
Once the device is placed in the laundry mode, the compressor and the fan work
continuously regardless of the ambient temperature and humidity level. The fan operates
at high speed, this can not be adjust in the laundry mode.
Defrosting function
This unit has an automatic defrosting function to protect it in case of low temperatures.
• If the ambient temperature is lower than 5° C, the compressor switches off and the fan
runs at high speed.
• If the ambient temperature is between 5° C and 12° C, the compressor runs for 30
minutes and then switches off for 10 minutes; the frost protection function will be
activated.
• If the ambient temperature between 12° C and 16° C, the compressor runs for 45
minutes and then switches off for 10 minutes; the frost protection function will be
activated.
• If the ambient temperature is equal to or higher than 16° C, the unit runs according to
the temperature measured on the inner sensor. The compressor operates for 30
minutes, then the temperature on the inner sensor will be measured one more time. If
the temperature on the inner sensor ≤ 1° C, the compressor switches off and the
defrosting function will be activated for 10 minutes.
Use of water tank
When the water full indicator illuminates, the tank is full, and the compressor and the fan will
stop operation. Please empty the water tank as follows:
1. Turn off and unplug the unit
and
to set the desired humidity level. The
to switch between high and low fan speed.
to set the laundry mode. This mode has been developed for
to turn the unit on or off.