ATTENTION: The heater has to be fixed on walls, where there are no combustible materials positioned,
directly above the appliance or in any case in the immediate vicinity. Otherwise, place the product at a
minimum distance of 1 m from the ceiling, from the lateral walls and from other thermo-sensitive materials.
MAINTENANCE
Attention: To improve efficiency of the product, it is recommended that you clean it from dust at least
every 80/100 hrs of functioning.
1. After use and before cleaning unplug the appliance and wait for the heater to cool. Take away the appliance
from the wall.
2. Wipe the outer shell with a soft damp cloth, do not use solvents.
3. ATTENTION: never touch the bulb with bare hands as contact with the human skin could damage the bulb.
Always use protective gloves. ATTENTION: for cleaning, never use alcohol solvents or other acids.
4. To replace the bulb, contact a specialized center.
5. Do not throw the box, use it to store the equipment.
6. When you don't use the appliance, store it in its original packaging and store in a dry place.
Model: 65437KW15
Item
Heat output
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous
heat output
Auxiliary electricity
consumption
At nominal heat output
At minimum heat
output
In standby mode
Model: 65437KW20
Item
Heat output
Nominal heat output
Minimum heat output
ISTR65437KW15-20_REV.2_05/18
fig. 2
Symbol
Value
Unit
P
1,5
kW
nom.
P
1,28
kW
min.
1,46
P
kW
max,c
el
N/A
kW
max
el
N/A
kW
min
el
N/A
kW
SB
Symbol
Value
Unit
P
2
kW
nom.
1,675
P
kW
min.
Item
Type of heat input, for electric storage local space
heaters only (select one)
manual heat charge control, with integrated
thermostat
manual heat charge control with room and/or
outdoor temperature feedback
electronic heat charge control with room and/or
outdoor temperature feedback
fan assisted heat output
Type of heat output/room temperature control (select
one)
single
stage
heat
output
temperature control
Two or more manual stages, no room
temperature control
with mechanic thermostat room temperature
control
with electronic room temperature control
electronic room temperature control plus day
timer
electronic room temperature control plus week
timer
Other control options (multiple selections possible)
room
temperature
control,
65437KW15-20
fig. 3
Unit
NO
NO
NO
NO
and
no
room
YES
NO
NO
NO
NO
NO
with
presence
NO