Two Point Mode Procedure - CARLO GAVAZZI LD30 BI10BP IO Série Manuel D'instructions

Masquer les pouces Voir aussi pour LD30 BI10BP IO Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
2) Dynamic teach command sequence
(Buttons are found in menu: Teach-in->Teach in Dynamic)
1. Press Teach SP1 Start here. (Parameter 2, SubIndex 0 = 71 (0x47)).
2. Press Teach SP1 Stop here. (Parameter 2, SubIndex 0 = 72 (0x48)).
3. Optional press Teach Apply. (Parameter 2, SubIndex 0 = 64 (0x40)).
3) Two value teach command sequence
(Buttons are found in menu: Teach-in->Two value teach)
1. Press Teach SP1 TP1 here. (Parameter 2, SubIndex 0 = 67 (0x43)).
2. Press Teach SP1 TP2 here. (Parameter 2, SubIndex 0 = 68 (0x44)).
3. Optional press Teach Apply. (Parameter 2, SubIndex 0 = 64 (0x40)).
Sensor

2.5.2.2. Two point mode procedure

1) Two value teach command sequence:
(Buttons are found in menu: Teach-in->Two value teach)
1. Press Teach SP1 TP1 here. (Parameter 2, SubIndex 0 = 67 (0x43)).
2. Press Teach SP1 TP2 here. (Parameter 2, SubIndex 0 = 68 (0x44)).
3. Optional press Teach Apply. (Parameter 2, SubIndex 0 = 64 (0x40)).
4. Press Teach SP2 TP1 here. (Parameter 2, SubIndex 0 = 69 (0x45)).
5. Press Teach SP2 TP2 here. (Parameter 2, SubIndex 0 = 70 (0x46)).
6. Optional press Teach Apply (Parameter 2, SubIndex 0 = 64 (0x40)).
Sensor
Hysteresis
SSC
TP2
SP1
ON
SSC
SP2
TP2
TP1
ON
TP1
OFF
SP1
TP2
TP1
OFF
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 | CARLO GAVAZZI Industri
Sensing distance
Sensing distance
19

Publicité

Table des Matières
loading

Table des Matières