8. Assemble inlet fitting - torque to 160-180 in-lbs.
9. Add a few drops of piston lube inside the inlet valve fitting,
the return tube fitting and the outlet valve. This will improve
priming the next time the pump is used.
10. Store in a clean, dry area.
11. Wipe down tubes, hose, and gun.
12. Store pump in an upright position.
IMPORTANT: Do not store inlet fitting and bypass/return fitting
immersed in hot solvents such as Acetone, Lacquer Thinner
or MEk. If you wish to soak these fittings, immerse in mineral
spirits.
NOTE: To remove material build-up and prolong inlet/
outlet valve life, soak the valves in lacquer thinner
overnight periodically. This will loosen up any
accumulated material between the O-ring and valve
seat.

Maintenance

Follow all other warnings to reduce the risk of an
injection injury, injury from moving parts or electric
shock. Always disconnect the pump before servicing!
After every use
• Oil inlet valve, outlet valve, and quick connect fittings with a
few drops of Titan Piston Lube.
Monthly
• Remove heel cover. Lubricate crank components with a few
drops of Titan Piston Lube. Insert an 9/32 allen wrench into
the shoulder screw and rotate the eccentric to draw oil into
cracks. Do not use grease.
Shoulder
screw
Heel cover
Screw
English

General Repair and Service Notes

1. Before repairing any part of the Transfer Pump, read the
instructions carefully, including all warnings.
IMPORTANT: Never pull on a wire to disconnect it. Pulling on a
wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be
sure that the problem is corrected. If the sprayer does not
operate properly, review the repair procedure to determine if
everything was done correctly. Refer to the Troubleshooting
section to help identify other possible problems.
3. Make certain that the service area is well ventilated in case
solvents are used during cleaning. Always wear protective
eyewear while servicing. Additional protective equipment
may be required depending on the type of cleaning solvent.
Always contact the supplier of solvents for recommendations.
4. If you have any further questions concerning your TiTAN
airless pump, call TiTAN:
Technical Service (U.S.) ...................................... 1-800-526-5362

Service

Replacing the Inlet Valve

NOTE: The inlet valve in this pump will need to be serviced
1. Perform CLEANUP procedure.
2. Adjust pressure to PRIME position.
3. Remove siphon and return tubes.
4. Remove material hose
5. Remove pump from turbine, ensuring power is removed.
6. Tip pump on its side to drain excess solvent. The unit should
be tipped on the side that contains the fittings for the siphon/
return tubes.
7. Remove inlet fitting.
Oil
8. Remove inlet valve assembly.
Oil
NOTE: To free the inlet valve assembly, gently rock the inlet
9. Replace with new inlet valve assembly.
10. Assemble inlet fitting - torque to 160-180 in-lbs.
8
Fax ................................................................. 1-800-528-4826
approximately every 10-20 hours of run time
depending on media type and speed setting.
valve assembly back and forth to free it from the
pump housing.
© Titan Tool. All rights reserved.
Inlet valve
Inlet tting