Table Des Matières; Introduction; Transfer Pump Controls - Titan Tool HVLP Transfer Pump 0524038 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table of Contents
Safety ................................................................................................ 2
Specifications ................................................................................... 2
Introduction ..................................................................................... 3
Transfer Pump Controls .............................................................................3
Setup ................................................................................................ 4
Converting the Gun to Pressure Feed ...................................................4
Mounting the Transfer Pump ...................................................................4
Connecting the Material Hose .................................................................5
Hose Configurations ....................................................................................5
Operation ......................................................................................... 6
Material Thinning .........................................................................................6
Preparing a New Sprayer ...........................................................................6
Preparing to Paint.........................................................................................6
Painting ............................................................................................ 6
Cleanup ............................................................................................ 7
Cleaning the Inlet / Outlet Valves ...........................................................7
Maintenance .................................................................................... 8
General Repair and Service Notes ..........................................................8
Service .............................................................................................. 8
Replacing the Inlet Valve ...........................................................................8
Replacing the Outlet Valve........................................................................9
Replacing the Seal and Piston ..................................................................9
Replacing the Pressure Setting Valve ..................................................10
Replacing the Motor ..................................................................................11
Troubleshooting ............................................................................ 12
Parts List ....................................................................................38-40
Electrical Schematic ...................................................................................41
Warranty ........................................................................................ 42

Introduction

The HVLP Transfer Pump is designed for use with CAPspray spray
systems. The Transfer Pump adds tremendous versatility to an
already complete system. This system improves user productivity
during larger spraying jobs by siphoning material directly from a
material container instead of spraying from a 1-quart cup.
Components of the HVLP Transfer Pump include a Transfer Pump,
material hose, siphon tube and a return tube.
This unit is to be used in conjunction with Titan CAPSpray series
turbines, sold separately (models CS75, CS95, CS105 or CS115).
Speed
setting
knob
Connector
Fuse
Siphon tube
tting
Return tube
(smaller diameter)
Siphon tube
(larger diameter)
© Titan Tool. All rights reserved.
ON/OFF switch
Pressure
setting knob
Outlet
valve
Return tube
tting
Siphon
lter
*Material hose not shown
With this HVLP spray system, you can achieve the highest quality
professional finish possible with little preparation or setup time.
Please review all the information contained in this manual before
operating the system.
Bypass Design
The pump is a positive displacement pump and will run continuously.
It differs from a typical airless piston pump in that during operation,
material will continuously circulate into the pump and out the return
tube unless the gun is triggered.

Transfer Pump Controls

Speed settings
The speed setting is used to adjust the volume of material available
to the spray gun. It is best to use the lowest speed possible in order
to maximize seal life. For most applications, LOW speed will perform
sufficiently while putting the least amount of wear of the seals.
LOW
• LOW - up to 14 fluid ounces per minute
• MED - up to 17 fluid ounces per minute
• HIGH - up to 20 fluid ounces per minute
• FLUSH - 40 ounces per minute (to be used only during
cleanup)
Pressure settings
The pressure setting is used to determine the amount of force used
to deliver the material. The pressure settings range from PRIME (no
pressure) to 6 (max pressure).
The pressure is determined by the figure shown at the 6:00 position
(when looking directly at the front of the pump) on the pressure
setting knob.
6:00
3
MEDIUM
HIGH
FLUSH
PRESSURE
PRIME
English