3.2.4
Shortcuts
Shortcuts can be used to quickly change settings
without calling up the menu of the controller .
Setting / Function
Baud rate
1200 bit /s
2400 bit /s
4800 bit /s
9600 bit /s
19 200 bit /s
Control protocol
Pelco-D
Pelco-P
Operating mode (zoom when rotating the joystick)
2D (zoom deactivated)
3D (zoom activated)
Password protection
Change of password,
new password (xxx),
make sure to remember it!
Locking*
Unlocking: password xxxx
Sound when pressing a key
Activation / deactivation
of sound
*will not change the menu setting PASSWORD ENABLE
3.2.5
Adapting the functions of the keys
TOUR, SCAN and MENU
In the factory settings, the keys will activate the
following control commands:
Key
Control command
[TOUR]
GO TO PRESET (=[CALL]) 76
[SCAN]
GO TO PRESET (=[CALL]) 99
[MENU]
SET PRESET (=[PRESET])
According to the camera to be controlled, differ-
ent commands may be required to activate the
function (
camera instructions) . To change
the preset number for the key command:
1) Use the numeric keys [0] ... [9] to enter the
corresponding preset number for the control
command .
If the number is not correct, use the key
[CLEAR] to delete it .
2) Keep the key to be changed pressed for
5 seconds .
12
Shortcut
[1]  [2]  [PGM]
[2]  [4]  [PGM]
[4]  [8]  [PGM]
[9]  [6]  [PGM]
[1]  [9]  [2]  [PGM]
[4]  [4]  [PGM]
[5]  [0]  [PGM]
[2]  [2]  [2]  [PGM]
[3]  [3]  [3]  [PGM]
[9]  [9]  [0]  [AUX]
 [x]  [x]  [x]  [x]
[9]  [9]  [1]  [AUX]
[x]  [x]  [x]  [x]
[9]  [9]  [9]  [AUX]
Preset number
95
3.2.6
Setting the cameras
Set the cameras to be controlled to the same
interface parameters and assign different bus
addresses (ID numbers) for individual control of
the cameras (
camera instructions) .
3.2.7
Resetting the controller
The controller can be reset to its factory settings
if required .
Factory setting
Baud rate
2400 bit /s
Control protocol
Pelco-D
Operating mode
Password protection
deactivated
Password
0000
Sound when pressing
deactivated
a key
Camera selection
1
(CAM ID)
Key function [SCAN]
control command "Call up preset 99"
Key function [TOUR]
control command "Call up preset 76"
Key function [MENU] control command "Save preset 95"
To reset:
1) Press the keys [SHIFT]  [MENU] to call up
the setup menu .
2) Use the joystick  to go to the following
menu item:
INITIALƊNO
3) Use the joystick  to change the setting to:
INITIALƊYES
4) Use the joystick  to change the setting to:
INITIALƊOK
5) Use the joystick  to go to the menu item
.
ƊEXIT
6) Use the joystick  to exit the menu .