10. Assembly of Shower Panel (2-part Function Block)
10.1 Remove the stainless steel housing or open the glass front.
☞
For further details please consult the Installation and Operating Instructions for the
fitting.
10.2 Use a hollow hexagon wrench to close the water volume regulators.
a: closed
b: open
10.3 Trigger the valve.
Spare parts
10.4 Disconnect the line connection between the solenoid valve cartridge and the
electronic module.
10.5 Remove the screws (c).
10.6 Remove the solenoid-valve cartridge (d).
10.7 Use a flat nose pliers to pull the existing filter (e) out.
10.8 Continue with
Retrofitting thermal disinfection
10.9 Remove the screws (f).
10.10 Unscrew the plug (g).
☞
Use an M8 screw to pull out the plug via the centre thread.
10.11 Insert the new filter.
☞
Important!
Ensure correct installation position. The rib of the filter must not lie on the flow-
through hole.
10.12 Insert the solenoid-valve cartridge.
10.13 Tighten the screws.
10.14 Connect the line connection between the solenoid-valve cartridge and the electronic
module (k).
l: Solenoid-valve cartridge mixed water
m: Solenoid-valve cartridge bypass, thermal disinfection
☞
Insert the adapter (n) if necessary.
10.15 Mount the stainless steel housing or close the glass front.
8
stap