Introduction

The Vetus GWDS allows waste water from the washbasin, shower,
dishwasher, air conditioner etc. to be pumped away by one piece of
equipment.
The equipment is not designed for industrial use.
The Vetus GWDS is not suitable for discharging faeces or toilet
paper!
Make sure that no large objects can get into the pump.
This could cause damage!
Install a shower drain with filter plate.
Make sure that rubber gloves are always available on board.
2

Working

When the water level in the container reaches a set level the motor
will be started by a signal from the built-in float switch and the water
will be pumped out.
3

Installation

3.1 General
Position the GWDS behind a wall or under a floor.
Make sure that the GWDS always remains accessible by fitting a
hatch in the wall or floor.
Always tighten all hose connections with good quality hose
clamps!
The Vetus GWDS is not fitted with a filter basket.
You should therefore always install a strainer in every pipe leading
to the GWDS.
6
110120.01
N
ote
Attach the 2 supplied fitting lugs (J) with the screws (I) on the bot-
tom of the container.
Use the 2 fitting lugs to fit the GWDS.
Preferably position the
GWDS amidships and
lengthwise in the ship.
Install the GWDS while the ship is at rest and then fit the GWDS on
a horizontal surface.
The GWDS is guaranteed to work correctly at angles up to 10˚ from
fore to aft and 20˚ athwartships.