4) Deleting transmitters
Note
The master transmitter programmed in 2) cannot be deleted. It can only
be overwritten (see 5).
1. Press the programming button on the master transmitter for 3 seconds.
The LED on the VC180 flashes briefly once to confirm.
2. Re-press the programming button on the master transmitter for 3 seconds.
The LED on the VC180 flashes briefly once to confirm.
3. Re-press the programming button on the master transmitter for 10 seconds.
The LED on the VC180 flashes briefly twice to confirm.
All transmitters (except the master transmitter) have been deleted from the
receiver.
5) Overwriting the master
1. Switch off the VC180 power for 10 seconds, then switch it back on.
The VC180 goes into the programming mode for 3 minutes.
Note
To ensure that the new master transmitter is programmed in the desired
VC180 only, all other receivers which are connected to the same power
supply must be deactivated from the programming mode.
To do so, after switching back on the power, execute a drive or stop
command using the transmitter for the given receivers.
2. Now press the programming button of the new master transmitter for
10 seconds.
The LED on the VC180 flashes briefly twice to confirm.
The new master transmitter has been programmed and the old master
transmitter deleted.