O P E R A T I O N
GB
Operation of Knee Control Unit: K351
Mount control unit onto your table/bench according to separate instructions (written on the drill template MU 3061). The
control unit needs to be turned "on" with the on/off switch. The "green" pilot lamp lights up. Select the desired max.
speed with the speed-selector lever by turning it clockwise. The selected speed is being shown at the LED reading. The
rate of revolutions will be continuously variable to the set speed. The handpiece comes to a stop by releasing the knee
lever. By using the reversal of rotation switch
The max. speed will be 30.000 rpm.
Operation of Table Top Control Unit: T351
The control unit needs to be turned "on" with the on/off switch. The "green" pilot lamp lights up. Select the desired max.
speed with the speed-selector lever by turning it clockwise. By operating the treadle switch, the selected speed will be
reached, which will be shown at the LED reading. In order to operate the unit without the treadle switch, the treadle
switch just needs to be unplugged. The unit operates at the set max. speed. By using the reversal of rotation switch
the direction of course of the handpiece will change (lamp lights up). The max. speed will be 30.000 rpm.
Do not clean handpiece with pressure air, also, the use of oil is prohibited!
Check the chuck at least once a month and clean it.
Motor overload protection
In case of an overload, the built-in electronics will shut itself and the motor off. The unit will be ready for further use.
Storage of the product
The storage of the product needs to be guaranteed (normal room temperature and normal humidity). You need to keep
the packaging for storage/transportation purposes.
Electromagnetic compatibility of product is given, tested after EMV.
MAINTENANCE OF THE CHUCK
Removing of the Bur:
1
To open the handpiece turn the motor grip sleeve in direction of arrow
and remove bur.
Never open handpiece while in use.
Removing of the Motor End Cap:
2
Unscrew motor end cap MU 4164 in direction of arrow.
Loosening of the Chuck:
3
Unscrew cap MU 4198 from the handpiece. Hold shaft of the motor with
box spanner MU 4136 and unscrew the chuck with the chuck key MU
0222 (direction of arrow).
I N S T R U C T I O N S
, the direction of course of the handpiece will change (lamp lights up).
,