INSTALLATION
The luminaire may only be installed by a professional electrician in accordance with local
legislation.
Always connect the luminaires when there is no incoming voltage.
Changing construction of the luminaire and making any changes to cabling is prohibited.
I-Valo luminaires are always delivered equipped with a preinstalled installation rail or
mounting holes drilled into the frame. Do not make any other holes of your own in the frame.
The luminaire can be installed directly to the ceiling or other installation surface from the
lugs at the ends of the luminaire.
When installing the luminaire, ensure that the fastening screws are not tightened too
much, as this may cause the frame to bend and the IP rating to change.
The luminaire can also be installed with a separately ordered installation fastener according
to the installation location:
- Suspension bracket D100
- Adjustable suspension double bracket D200
- Chain suspension 6021
- Stepless wall bracket 6035 (2 pcs)
- Wall bracket 6060 (2 pcs)
- Wall bracket 6061
- Pole bracket 6063
- Pipe bracket 6065
- Wire bracket 6079
- Adjustable rail bracket 6036 (2 pcs)
USAGE & MAINTENANCE
The luminaire may only be used in an environment for which it has been designed according
to its rating label.
Before performing maintenance, voltage must be disconnected from the luminaire. It takes
several minutes for the luminaire components to cool down.
The luminaire may not be used without its cover glass or PC/acrylic cover.
The conditions of the installation rail, bracket and sealing surfaces should be checked
regularly.
A damaged luminaire must not be used; voltage must be disconnected from it and it must be
repaired.
An unstable electrical grid may damage the electronic components of the luminaires.
Temperature and the quality of the supply voltage affect the service life of the control gear.
The estimated failure rate is 0.2% per each 1,000 operating hours at the luminaire's maximum