Use in winter season
We recommend to install the trough drinker into a water circuit means of a connection set ¾" Ref. 103.1984. The water circuit is then connected to a SUEVIA
Heating Unit. This guarantees a frost-protected use throughout the year. See heating unit instructions.
Heated version
Heating element Ref. 131.0524 (24 V, 80 W) can be installed at any time to keep water inside of the bowl frost-free. For frost protection of the water line a
frost protection heating cable Ref. 101.0861 (24 V, 20 W, 2 m / 6,56 ft), or Ref. 101.1863 (24 V, 30 W, 3 m / 9,84 ft) can be supplied. The heating cable
should be wrapped around the feed pipe and connected to the heating element of the drinker in parallel to the power supply cable, coming from the transfor-
mer. If this heating cable is installed on plastic pipes, make sure that this water pipe is suited for warm and cold water. For better heat distribution the water
pipe has to be wrapped first with an aluminium adhesive tape Ref. 101.1099. For increased frost protection of the valve an installation of a valve heating is re-
commended Ref. 131.0527 (24 V, 7 W). For power supply a transformer is necessary. Transformer should be mounted outside of animal's reach! Only cold
weather conditions require constant heating. When it is not so cold outside, heating can be interrupted by drawing out the transformer's plug. As alternative to
this for automatic switch on/off of the treansformer we recommend to install SUEVIA Thermostat Ref. 101.0389.
Electric connection
All installation, maintenance and inspection works must be carried out only by an authorised and qualified specialist. Local norms must be respected.
The assembly instruction of the respective electric devices are to be followed.
Fire prevention
A minimum distance of 30 mm to flammable material should be held.
Changing of valve side from the right (as-delivered) to the left side
• Cut off the water supply.
• Unscrew 6-edges fixation screw at middle of the top cover. Untighten the nuts 102.0254 located on both sides of the drinker.
• Take off the cover 132.6006.
• Remove the valve.
• Take off the cover 132.6008.
• Mount the valve on the opposite side (water connection from the left).
• Assemble it in reverse order.
• Let the water flow Function check.
Protection bar
A protection bar Ref. 131.1391 or 131.1394 can be installed as option for protection of the drinker.
Connection to a water circuit
¾"
Mounting of the heating
element 131.0524
131.0524
Water
103.1984
connection
or
View of the drainage plug
Changing of valve side
Connection from the left side
SUEVIA
SUEVIA
from below
Connection from the right side
SUEVIA
SUEVIA
View of the drainage plug
from inside
Water
connection
5