ENGLISH
MANUAL installation:
Don't yet connect the DLP-6 to your PC!
The installation file for the driver can be found on the supplied CDROM or you can download it from
the SYNQ-website (see download section of the DLP-6 product page).
UNZIP the file and double-click the exe-file named "PL-2303 Driver Installer.exe" and follow the
instructions to install the driver properly.
To check if the driver is installed, open the Windows
device manager and check if the driver is available, you
can also check which COM-port is emulated (in most
cases it will be COM3, as shown on the picture) To be
able to see the driver listed, you should connect the DLP-
6 to your PC and turn it on.
Remark: depending on the hardware inside your DLP-6
the drivername shown in windows can be different!
Part2 – installing the DLP-6 PC-software
The DLP-6 PC-software can be found on the supplied CDROM or you can download it from the SYNQ-
website (see download section of the DLP-6 product page).
Double-click the file named "DigitalSpeakerSetup_V110 SYNQ Audio.exe" and follow the instructions to
install the software.
Part3 – first time use
First connect the DLP-6 with your PC via USB or RS485.
The USB output of the PC will be treated by the software as an RS-232 connection. Therefore you will
have to set the correct RS232 port when you use the software for the first time:
Start the PC software. In the left upper corner you will notice the sign on the right, indicating
that the software is not connected to the processor.
Open the "CONFIG" menu and select the "RS-232" option.
Normally you should choose "COM3". To be sure you can check the COM-port in the Windows
manager.
Open the "CONFIG" menu again and select "OnLine": a popup window will open where you have to
select "DLP-6:2In6Out"
If the software can connect to the processor than you should see the sign on the right. If this
doesn't work, you should also select some other COM-settings and try again to establish a
connection.
CHECKING THE SOFTWARE VERSION
Open the "HELP" menu and select the "About" option. In the popup window you can see the software
version and program build:
SYNQ
11/96
®
OPERATION MANUAL
®
®
device
DLP-6
ENGLISH
USING THE SOFTWARE:
Keep in mind that the software is always connected to the processor so all parameters and settings you
change in the software are immediately sent to the DLP-6! This means that you have "live" interaction with
the audio of your audio system. On the screen you can see that the PC software has a very easy interface
with clickable icons.
You can click the icons to start your setup (start with the "Source" icons), you can choose a preset ("config"
menu, option "preset") or you can simply load a custom made program to further tune it:
Program Manager
Choose option "Device Program Manage" in the
menu Program. the window "memory" appears.
This window allows you to send programs between
the PC and the processor and save/load them on
your laptop. These are the different options:
Store
to
device:
used to
store
the
configuration in the DLP-6. First select one of the 30
memory locations before you press the "Store To
Device" button! You will be asked for a proper name
and if you are sure you want to overwrite the current
memory location in the processor.
Recall from device: used to recall one of the 30
memories in the DLP-6 and transfer it to the PC so
you can edit/store it.
Store to PC: used to store the selected memory (1
out of 30) to a file on your PC.
Recall from PC: used to recall one memory, stored
on your PC, and load it to the selected memory location.
Store all to PC: used to store the complete set of 30 memories from the DLP-6 in a file on your PC.
Recall all from PC: used to recall a file, containing a set of 30 memories, from your PC and send it to the
DLP-6.
Linking the parameters on inputs and outputs
In many cases the parameters of the in/outputs should simply be equal. To make life easier you can link
two or more in/outputs you only have to change the parameters of one in/output, the linked in/output(s)
will be set a the same time!
SYNQ
12/96
®