Operation
12 Advanced Inverter Settings Screens (continued)
The advanced inverter settings are for technicians only,
and a pop-up message appears when you tap the
advanced inverter icon.
13 Advanced Inverter Settings Notification
Tap the CANCEL button to return to the Power screen, or
tap the GO ANYWAY button to proceed to the
Advanced Inverter screen.
There are some configurable settings available from
I
the inverter LCD display.
From the Advanced Inverter Settings screen, technicians
can control or monitor the following functions by tapping
the expand/contract arrows, toggle buttons, EDIT, and
OK buttons as applicable:
• Inverter Ignition Control: This button adjusts the
ignition control setting.The default setting is Off. Tap
the tumbler to select Automatic, Lockout, or Off.
12
• LBCO Voltage: This button adjusts the voltage
setting.The default setting is 10.5 V. Tap the Edit
button to adjust the value in 0.1 V increments. The
inverter is able to recover automatically at LBCO
voltage + 0.2 V.
• LBCO Shutdown Delay Timer: This button adjusts
the shutdown timer.The default setting is 300 sec. Tap
the Edit button to adjust the value in 10-sec increments.
• LBCO Recovery Voltage: This button adjusts the
recovery voltage setting.The default setting is 13.1 V.
Tap the Edit button to adjust the value by 0.1 V
increments. Selecting a value higher than the battery's
actual fully-charged voltage level will not activate the
auto-recovery feature. Manually reset the inverter
charger when the low-battery cut-off event occurs.
• Power Save Time: This button sets the countdown
timer to shut down the inverter operation automatically
to reduce the battery discharge and to preserve the
battery life. The countdown timer range is between 1
and 25 hours. The default setting is 25 hours. During a
continuous inverter operation, the countdown initiates
when the power from the AC load drops to less than
approximately 50 W and remains below this level.
After reaching the end of the countdown timer, the
inverter charger automatically shuts down.
• Power Save Mode: This button enables the power
save mode setting. The default setting is Off. Tap the
toggle button On to allow the inverter charger to go to
load sense mode automatically by sending short
pulses to further reduce the battery discharge. Power
save mode ends when a load greater than 25 W is
connected.
• Output Frequency: This button adjusts the output
frequency setting. The default setting is 60 Hz.
Depending on the country or location, tap the toggle
button to change the value to 50 Hz and then turn the
unit Off and On again for the change to take effect.
• Output Voltage: This button adjusts the output
voltage setting. The default setting is 120 V. Tap the
tumbler to select the value.
• Inverter Output Power Limit: This button adjusts
the wattage limit for outgoing power. The default
setting is 2 kW. Tap the Edit button to adjust the value
in 100 W increments. Use with the Inverter Output
Power Limit Timer if pairing with a lithium ion battery.
Dometic Interact
EN