CAUTION
Do not put foreign objects into the
■ ■
plug receptacle.
Check the amperage of the receptacles, and be sure not
■ ■
to take a current exceeding the specified amperage.
Be sure that the total wattage of all appliances
■ ■
dose not exceed the rated output of the generator.
NOTE
When the AC circuit breaker turns off during
operation, the generator is over loaded or the
appliance is defective.
Stop the generator immediately, check the
appliance and / or generator for overloading, and
have repaired as necessary by DOLMAR factory
or authorized service center.
(d) Turn on the switch of the appliance.
(2) DC APPLICATION (See Fig. 4 4 -t t )
The DC terminal is used only for charging 12 volt
batteries. It provides up to 12V-8.3A (100W) of
maximum power.
q Positive terminal (RED)
w Negative terminal (BLACK)
CONNECTION OF CABLE :
Connect positive terminal (red) on generator
■ ■
to positive (+) terminal on battery.
Connect negative terminal (black) on
■ ■
generator to negative (-) terminal on battery.
SAFETY PRECAUTIONS WHILE CHARGING
An explosive hydrogen gas is discharged
■ ■
through vent holes in the battery during the
charging process. Do not allow spark or open
flame around the generator or battery during the
charging process.
Electrolyte fluid can burn eyes and clothing.
■ ■
Be extremely careful to avoid contact. If injured,
wash the affected area immediately with large
quantities of water and consult a doctor for
treatment.
When charging a large capacity battery or
■ ■
totally discharged battery, excessive current
may force the DC breaker to turn off.
In such cases, use a battery charger to charge
a large battery with AC output.
Battery defects may cause the DC breaker to turn off.
■ ■
Check the battery before replacing the DC breaker.
3. STOPPING THE GENERATOR
(a) Turn off the power switch of the electric
equipment and unplug the cord from receptacle
of the generator.
(b) Allow the engine about 3 minutes to cool down
at no load before stopping.
(c) Turn the engine switch to the position "
(See Fig. 4 4 -y y )
4. OIL SENSOR (See Fig. 4 4 -u u )
(a) The oil sensor detects the fall in oil level in the
crankcase and automatically stops the engine
when the oil level falls below a predetermined
level.
(b) When engine has stopped automatically, switch
off generator's AC circuit breaker, and check the
oil level.
Refill engine oil to the upper level as instructed
on page 6 and restart the engine.
(c) If the engine dose not start by usual starting
procedures, check the oil level
q OIL SENSOR
CAUTION
Do not remove OIL SENSOR PROBE when
refilling with oil.
Remove oil filler cap on the opposite side
of carburetor.