E. Test function
The test function tests the switching function of the control
unit. The prerequisite is that the window is closed and
the green „Power" LED lights up. If the test button is now
pressed, an acoustic signal is heard and the „Power" led
glows red. This state is maintained for as long as the test
button is pressed.
F. CE information
Under the influence of strong static, electrical or high
frequency fields (discharges, mobile phones, wireless
systems, microwaves) the performance of the device(s) may
be impaired.
G. Malfunctions
The control unit constantly monitors the wires to the
magnetic switch. If faults occur, the control unit switches off,
an acoustic signal is emitted and the contact circuit in which
the fault has occurred is indicated.
If „Sensor 1" lights up, the fault is located in the circuit with
the cable colours „yellow/green".
If „Sensor 2" lights up, the fault is located in the circuit with
the cable colours „white/red".
In the event faults, please check over the wires and the
terminals in the distributor!
The magnetic switches are NO or make contacts (contacts
that are closed when the when is open). When the window is
open, the loop resistance is approx. 6700 Ohm.
H. Technical specs
Mains voltage
Mains switching capacity
Protection code
Tested as per DVGW VP121:2004
Never carry out repairs yourself!
WARRANTY
2 years warranty from date of purchasing,
on base of correct using.
The producer is not responsible for consequential damages
which are effected directly or indirectly from this item.
Subject to change without prior notification. In the
framework of product updates and device optimization, the
contents may vary from the packaging specification.
18
230 V ~ , 50 Hz,
approx. 3 W
1300 W, 6A
IP 20 (only for
dry rooms)