Frame description:
• Byte 2: Type of the sensor on channel A. Configured by the user (register 320).
• Bytes 3 to 5: Value measured on channel A.
• If the type of sensor is 0-10V: The value is expressed in µV
• If the type of sensor is 4-20mA: The value is expressed in nA
• Byte 6: Type of the sensor on channel B. Configured by the user (register 322).
• Bytes 7 to 9: Value measured on channel B.
• If the type of sensor is 0-10V: The value is expressed in µV
• If the type of sensor is 4-20mA: The value is expressed in nA
In the example in grey this gives:
• Byte 2=0x02: register 320, channel A configured for a 4-20mA sensor
• Bytes 3 to 5=0x0C3500=800,000 in decimal i.e. A value measured on channel A of: 800,000,x10=8,000,000nA i.e. 8mA
• Byte 6=0x01: register 322, channel B configured for a 0-10V sensor
• Bytes 7 to 9=0x4C4B40=5,000,000 in decimal i.e. a value measured on channel B of: 5,000,000 µV i.e. 5V

4.1.7 Summary of the conditions of the transmission of the uplink frames

The table below summarizes the conditions of the transmission of the different uplink frames:
Code
Description
0x10
Product configuration data frames
0x11
0x12
0x13
0x14
0x20
Frames of information on the network
configuration
0x30
Keep Alive frame
0x31
Reply frame to a register value request in
a downlink frame
0x42
Data Frame

4.2. Downlink frames

LoRaWAN technology makes it possible to transmit information to the product from the network (downlink frame).
The class A of the LoRaWAN specification allows the product to receive information from the network by proposing two listening windows after
each uplink communication (uplink frame).

4.2.1 Product configuration request frame

This frame allows us to inform the product via the network that it must resend the product configuration uplink frame (0x10).
0
1
Code
0x01
X
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x01
• Periodically if the inputs are disabled (period defined by the register 300)
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x02
• Periodically in «event» mode
• Reception of a downlink frame 0x40
• Start-up of the product
• Event on an digital input configured in event mode
• Passing a threshold (event mode)
• The end of the period on input configured in periodic mode
2
3
X
X
Sending conditions
4
5
PAYLOAD
X
X
FR
EN
6
7
X
X
Page