Display
ON/OFF
∙ Press this button, a sound beep and the display shows the current humidity. The
device starts in the standard mode (air moistening – high ventilation for 1 minute
– ionisation).
∙ After 1 minute, the device turn to the automatic program and the symbol
∙ If the humidity is higher than 60%, the device turns off automatically.
∙ If the humidity is between 45% and 59%, the device works with low ventilation
speed.
∙ If the humidity is below 45%, the device works with high ventilation speed.
∙ By pressing the On/Off button again, the device turns off. The ventilation keeps
running for 30 seconds.
Humidity
∙ The relative humidity in a room at 20°C should be:
∙ bedroom or living room:
∙ sickroom:
∙ library:
∙ By pressing the button, the humidity can be set in steps of 40% - 50% - 60%
- 70%.
∙ If the ambient humidity is above the set humidity, the air moistening stops and the
display shows
.
∙ If the humidity is 1% - 14% below the set humidity, the ventilation works at low
speed.
∙ If the humidity is more than 15% below the set humidity, the ventilation works at
high speed.
∙ The colour of the display changes depending on the humidity:
∙ Red: < 40% RH
∙ Green: 40 – 59% RH
∙ Blue: > 60% RH
∙ The colour change of the display can be turned off by pressing the On/Off button
longer than 3 seconds.
14
45-60% RH
40-50% RH
40-50% RH
1) ambient humidity
2) humidity level
3) ventilation
4) ionisation
5) child lock
6) water preheating
7) water level
8) remaining time
blinks.