Télécharger Imprimer la page

Storch Opti-Air Mode D'emploi page 34

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Switch Opti -Air to full (2) output on the on/off switch and
align the air bellows in the window so that there is no lon-
ger an air gap between the window and frame. The short
end is intended to seal the bottom window wing and the
window drip, the long end to seal the sides and top towa-
rds the window wing and frame. If the air bellows are not
sufficiently dimensioned for large windows, add suitable
seals, such as blankets, etc.
The air bellows feature an air outlet that can be opened
or closed using a cord. Adjust the opening to control the
amount of extracted ambient air and the volume as well
as sealing of the air bellows in the window.
Troubleshooting
Device does not start:
= Check the power supply
= Check the mains cable for damage
= Check the turbine impellers for obstructions
Translation of the original instruction
Setting the temperature
On /off switch, turbine:
2
= Full turbine output
1
= 50% turbine output
0
= Off
Heating coil:
2,000 W
= Full heating output
1,000 W
= 50% heating output
0 W
= Heating coil off
Temperature settings/temperature controller
for the heating coil
Opti -Air can heat up externally drawn in air. As a result,
ambient air is heated up to a pleasant temperature and
thus creates a pleasant working environment. Additio-
nally, hot air absorbs more moisture than cold air and
therefore the device guarantees faster drying processes
because the air is once again extracted to the outside. The
drying process is also selectively accelerated by hot air.
The temperature of the supplied air can be continuous-
ly adjusted in individual heating levels 1 and 2 using the
tempe rature controller.
The hottest air is output at maximum temperature con-
troller setting, maximum heating coil output (2,000 W)
and blower level 1.
Always disconnect the device from the mains prior to
working on it.
If the device has switched off due to overheating, allow
the device to cool down for a few minutes until the ther-
mal switch re-engages.
If the device still fails to operate, please contact the
STORCH Service Hotline or an authorised Service Station.
34

Publicité

loading

Ce manuel est également adapté pour:

61 40 00