SLEEP MODE
The SLEEP mode enables you to save energy.
1. Set the MODE selector to cool, dry or heat.
2. Press the SLEEP button.
3. The
mark appears on the display. Press the SLEEP
button again to release the SLEEP function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or heat the room to the
set temperature, and then the thermostat will make the unit pause.
EG
After about 1 hour, the air conditioner will automatically reset the
set temperature as follows (also refer to graphs).
OPERATING MODE
Heating
Cooling and Dehumidifying
When the room temperature reaches the new set value, the
thermostat will cause the unit to pause. After about 1 hour the
temperature will be raised by 1 °C in cooling, or lowered by 1 °C
in heating. This enables you to save energy without sacrificing
your comfort.
COOLING AND DEHUMIDIFYING
Setting temperature
1°C
1°C
1 hour
1 hour
SETTING THE TIMER
A) HOW TO SET THE OFF TIME
1. Press the ON/OFF button to start the air
conditioner.
2. Press the TIMER button till the OFF sign
blinks.
3. Press the + or - (HOUR) button until the
desired value is displayed.
4. Press the SET button to activate the
timer.
B) HOW TO SET THE ON TIME
1. Press the ON/OFF button to stop the air conditioner.
2. Press the TIMER button till the ON sign blinks.
3. Press the + or - (HOUR) button until the desired value is
displayed.
4. Press the SET button to activate the timer.
SET TEMPERATURE CHANGE
Lowered by 1 °C
Raised by 1 °C
Room temperature
TIME
HEATING
Setting temperature
Room temperature
1 C
1 C
1 hour
1 hour.
2
1
C) HOW TO SET A PROGRAM FOR DAILY ON/OFF OPERATION
(OR VICEVERSA)
1. Press the TIMER button till the ON sign blinks.
2. Press the + or - (HOUR) button until the desired value is
displayed.
3. Press the TIMER button again, the OFF sign blinks.
4. Press the + or - (HOUR) button until the desired value is
displayed.
5. Press the TIMER button, then the SET button to activate the
timer.
D) HOW TO CLEAR THE TIMER
Press the CLEAR button if you want that every timer operation will
be cleared.
NOTE
If the procedure to set the timer is not completed, by pushing the
SET button, within 15 seconds the timer operation will be cancelled
and the last set-up is restored.
ADJUSTING THE AIR FLOW DIRECTION
HORIZONTAL (manual)
The horizontal air flow can be adjusted by moving the vertical
vanes to the left or right, as indicated in the following figures.
VERTICAL (with remote control unit)
The remote control gives you the possibility to control the flap in
two way:
1. Push the
again the flap stops immediately.
TIME
2. Push the
Set vertical vanes to the front position during COOLING/DRY
operation if humidity is high.
If the vertical vanes are set to the left-most or right-most
position, condensation will form around the air outlet and
drip off.
Do not move the flap with your hands when the air conditioner
4
is running.
3
Vertical vane
8
button to start the flap sweep. If you push
button to move the flap step by step.
CAUTION
CAUTION
Left
Right