Cleaning And Maintenance - HQ Power VDP250SC6/2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Channel configuration
CHANNEL 1: 7 colours + white
CHANNEL 2: 7 gobos + open
CHANNEL 3: strobe
CHANNEL 4: gobo rotation
CHANNEL 5: pan
CHANNEL 6: tilt
Detailed DMX values per channel
Description
CHANNEL 1
Colour wheel
CHANNEL 2
Gobo Wheel
CHANNEL 3
Strobe
CHANNEL 4
Gobo Rotation
CHANNEL 5
Pan
CHANNEL 6
Multiple units can be chained together for synchronous operation by means of the provided DMX cable

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections...
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician service the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts apart from the lamp and the fuse (see "Installation").
8. Contact your dealer for spare parts if necessary.
VDP250SC6/2
From
0
32
64
96
128
160
192
224
0
32
64
96
128
160
192
224
0
15
30
251
0
121
138
0
Tilt
0
To
Function
31
White
63
Red
95
Yellow
127
Purple
159
Green
191
Orange
223
Blue
255
Pink
31
Open
63
Stars
95
Dotted Circle
127
Spiral
159
Line
191
Triangle
223
Star
255
Hand
14
Shutter closed
29
Shutter closed
250
Strobe (slow -> fast)
255
Shutter open
120
Counterclockwise rotation (slow -> fast)
137
No rotation
255
Clockwise rotation (slow -> fast)
255
8 bit
255
8 bit
4
VELLEMAN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Extreme 250

Table des Matières